Ferraz Shawmut MPDB66662 Non Stock
printPrint
  1. pin-int

Ferraz Shawmut MPDB66662

MPDB66662 Intermediate Open Style Power Distribution Block, 600 VAC, 310 A, 2 Poles, 6 AWG to 350 kcmil Wire, Polycarbonate

  • MPN: MPDB66662
  • UPC: 782001455095
  • Min. Order Qty: 1
  • Quantity Interval: 1
  • loading loading
Ferraz Shawmut MPDB66662

The next generation power distribution block (PDB). MERSEN power distribution blocks provide a safe and easy method of splicing cables, splitting primary power into secondary circuits and fulfilling requirements for fixed junction tap-off points. Unless noted otherwise, all blocks are UL and CSA approved while meeting spacing requirements for feeder and branch circuits in conjunction with UL 508A and the National electrical Code®. PDB options include single or dual conductor primary inputs and up to 30 secondary outputs. Specialty blocks are available allowing for up to 7 primary inputs.

Ferraz Shawmut Power Distribution Block, Intermediate Open Style, Series: MPDB, 600 VAC, 310 A, 2 Poles, 1 Primary Connections/Pole, 6 Secondary Connection/Pole, 6 AWG to 350 kcmil Wire, 100 kA Short Circuit Current, Polycarbonate, Black, 3.25 in H x 3.57 in W x 5 in D

Color      :      Black
Dimensions      :      3.25 in H x 3.57 in W x 5 in D
Primary Connections/Pole      :      1
Secondary Connection/Pole      :      6
Series      :      MPDB
Short Circuit Current Rating      :      100 kA
Type      :      Intermediate Open Style
Voltage Rating      :      600 VAC
Amperage Rating      :      310 A
Number of Poles      :      2
Wire Size      :      6 AWG to 350 kcmil
Material      :      Polycarbonate
  • Aluminum connectors accept both aluminum or copper wire while copper connectors accept copper wire only
  • Connectors are all 1-piece tin plated
  • Insulators are virtually unbreakable, made of glass-filled polycarbonate
  • See-through, hinged safety covers provide a greater degree of safety and shock resistance where required
  • Hinged covers can be installed without tools
  • 1 in through air and 2 in over surface between uninsulated live parts of opposite polarity meets requirements for feeder and branch circuit applications of UL 508A
  • Polycarbonate safety covers provide dead-front protection
  • One cover is needed for each pole
  • Each cover has a test probe hole in the center for circuit checking
  • 6 AWG to 350 kcmil Cu line, 14 to 2 AWG Cu load
  • pdfCatalog https://assets.unilogcorp.com/2/ITEM/DOC/Ferraz_Shawmut_MPDB62100_Catalog.pdf
  • pdfSpecification Sheet https://assets.unilogcorp.com/2/ITEM/DOC/IDW_DOCUMENT_fa0c869d3e672bbdf791e74980528d074fea527e584ef5e2d2030ff8e49a4164.pdf