EcoSystem® compact ballasts provide high performance dimming for any compact fluorescent application, including within an EcoSystem® lighting control System. EcoSystem® compact ballasts offer 100% to 5% dimming, providing both energy savings and lighting flexibility.
EcoSystem® Digital Ballasts, Dimming Studded, T4 CFL Lamp, 32 W Lamp, 66 W Wattage, 120 VAC, 0.55 A, 50/60 Hz Frequency, Programmed/Rapid Start, 50 deg F Minimum Starting, Total Harmonic Distortion: <10%, Power Factor: 0.95, Yes Dimmable, 2 Lamps, Thermal Protection: Class P, 4-Pin Lamp Base, Ballast Factor: 0.95, NEMA 1 Enclosure, 167 deg F, Fixture Mounting, 4-9/10 in L x 3 in W x 1 in H Dimensions
Amperage Rating |
: |
0.55 A |
Dimensions |
: |
4-9/10 in L x 3 in W x 1 in H |
Dimmable |
: |
Yes |
Enclosure Type |
: |
NEMA 1 |
Frequency Rating |
: |
50/60 Hz |
Lamp Base Type |
: |
4-Pin |
Minimum Starting Temperature |
: |
50 deg F |
Mounting Type |
: |
Fixture |
Number of Lamps |
: |
2 |
Power Factor |
: |
0.95 |
Temperature Range |
: |
167 deg F |
Thermal Protection |
: |
Class P |
Total Harmonic Distortion |
: |
<10% |
Type |
: |
Dimming Studded |
Wattage |
: |
66 W |
Lamp Type |
: |
T4 CFL |
Lamp Wattage |
: |
32 W |
Voltage Rating |
: |
120 VAC |
Start Type |
: |
Programmed/Rapid |
Ballast Factor |
: |
0.95 |
- Continuous, flicker free dimming from 100% to 5%
- Compatible with EcoSystem® energy saver Node unit, GRAFIK Eye® QS with EcoSystem® unit, PowPak™ dimming module with EcoSystem® unit, and Quantum systems, allowing for integration into an existing/planned EcoSystem® lighting control system
- Supports standard 3-wire line-voltage phase control technology
- Programmed rapid start design ensures full rated lamp life while dimming and cycling
- Lamps turn on to any dimmed level without flashing to full brightness
- Low harmonic distortion throughout the entire dimming range
- Frequency of operation ensures that ballast does not interfere with infrared devices
- Inrush current limiting circuitry eliminates circuit breaker tripping, switch arcing, and relay failure
- Ultra-quiet operation
- Protected from miswires of any input power to control lead, or from lamp leads to each other and/or ground
- End-of-lamp-life protection circuitry ensures safe operation throughout entire lamp life
- Nonvolatile memory restores all ballast settings after power failure
- 100% compatible with all Lutron 3-wire fluorescent controls and EcoSystem® digital controls
- 100% performance tested at factory
- Ballast is grounded by the specified terminal or by a mounting screw to the fixture
- Ballast mounts using two mounting tabs or studs within a fluorescent fixture
- Within a fluorescent fixture mounting, K case size
- 4560 lumens
- 69.1 lm/W system efficacy
- 1.44 ballast efficacy factor