ProSoft Technology 5105-MCM-PDPS Non Stock
printPrint
  1. pin-int

ProSoft Technology 5105-MCM-PDPS

5105-MCM-PDPS Modbus Master/Slave To Profibus DP Slave Gateway, PDPS/MCM Protocol, 50/60 Hz, RS232/422/485 Interface

  • MPN: 5105-MCM-PDPS
  • Min. Order Qty: 1
  • Quantity Interval: 1
  • loading loading
ProSoft Technology 5105-MCM-PDPS

The ProLinx modbus master/slave to PROFIBUS DP slave gateway creates a powerful connection between devices on a modbus network and PROFIBUS DP master devices. This stand-alone DIN rail mounted protocol gateway provides one configurable serial port and one DB9F PDPS port. The modbus protocol driver supports master and slave implementations of the protocol. All modbus serial ports are individually configurable, providing a very powerful and flexible host or device interface solution. The PROFIBUS DP slave protocol driver supports the PROFIBUS V0 slave implementation, providing powerful data transfer capability between the ProLinx module and Siemens PLCs or other hosts. User configurable data mapping and DP port operation make the interface an easy to use and powerful data transfer tool.

ProSoft Technology Modbus Master/Slave To Profibus DP Slave Gateway, PDPS/MCM Protocol, 50/60 Hz, RS232/422/485 Interface Type, 110 to 115 kbps Data Transfer Rate, Serial Port, 2 Ports, 5.2 in H x 2.07 in W x 4.52 in D, Environmental Conditions: 5 to 95% Humidity

Data Transfer Rate      :      110 to 115 kbps
Dimensions      :      5.2 in H x 2.07 in W x 4.52 in D
Environmental Conditions      :      5 to 95% Humidity
Number of Ports      :      2
Port Type      :      Serial
Protocol      :      PDPS/MCM
Frequency Rating      :      50/60 Hz
Interface      :      RS232/422/485
  • 18 to 32 VDC allowed positive, negative, GND terminals 2.5 mm screwdriver blade power supply
  • -4 to 122 deg F operating temperature
  • Power and module status, application status, serial port activity, serial port error status LED indicators
  • DB-9M RS-232 only no hardware handshaking configuration serial port
  • 10 base-T half duplex RJ45 connector link and activity LED indicators electrical isolation 1500 Vrms at 50 Hz to 60 Hz for 60 sec EtherNet port
  • EtherNet broadcast storm resiliency is equal to less than or equal to 5000 [ARP] frames/sec and less than or equal to 5 min duration
  • Modbus plus connector two DB9 female standard modbus plus connectors are application ports
  • 2500 Vrms port signal isolation per UL 1577, 3000 VDC minimum port to ground and port to logic power isolation serial port isolation
  • 500 mA maximum at 32 VDC power supply
  • videoVIDEO LINK http://www.youtube.com/watch?v=-C62uCsc4cE