HELUKABEL® SUPERTRONIC® Control Cable, EMC Preferred, 300 VAC, 4 Conductors, Bare Copper Conductor, 24 AWG Conductor, 5.1 mm OD, PVC Insulation, PVC Jacket, Gray Jacket, -40 to 80 deg C
Insulation Material |
: |
PVC |
Jacket Color |
: |
Gray |
Jacket Material |
: |
PVC |
Outside Diameter |
: |
5.1 mm |
Temperature Rating |
: |
-40 to 80 deg C |
Type |
: |
EMC Preferred |
Voltage Rating |
: |
300 VAC |
Number of Conductors |
: |
4 |
Conductor Type |
: |
Bare Copper |
Conductor Size |
: |
24 AWG |
- Low-adhesion
- The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
- 1500 VAC core/core, 1000 VAC core/screen test voltage
- Up to 80x106 cJ/kg (up to 80 Mrad) radiation resistance
- -40 to 80 deg C temperature range for fixed installation
- Bare copper conductor, fine wire unilay with short lay length
- Core insulation of PVC class 43 acc. to UL Std.1581
- Core identification to DIN 47100 colored
- Cores stranded in layers with optimal lay length
- Wrapping of fleece between the layers of stranding
- Wrapping over the outer layer
- Braided screen of tinned Cu wires, coverage approximately 85 percent, for applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing speeds etc
- Core wrapping with fleece, the copper screen effectively protects against internal and external interference
- Outer sheath of oil-resistant special PVC, compound type TM5 to DIN VDE 0281 Part 1 or class 43 acc. to UL Std.1581, long service lives guarantee reliable function and good cost efficiency
- Fine wire, a highly-flexible PVC control cable suitable for frequent and fast lifting and bending stresses in machines and tool building, robot systems and on constantly moving machine components
- Special PVC drag chain cable approved to UL Style 2464
- PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)