Total Protection Solutions™ TK-LT120-15A-DIN2 Non Stock
printPrint
  1. pin-int

Total Protection Solutions™ TK-LT120-15A-DIN2

TK-LT120-15A-DIN2 LT Series Surge Protection Device, LoadTrack™, 15 A, 25/50 VAC/24/65 VDC, 47 to 64 Hz, 100 kA SCCR

  • MPN: TK-LT120-15A-DIN2
  • Min. Order Qty: 1
  • Quantity Interval: 1
  • loading loading
Total Protection Solutions™ TK-LT120-15A-DIN2

Total Protection Solutions™ LoadTrack™ Surge Protection Device, Series: LT Series, 15 A, 25/50 VAC/24/65 VDC Electrical Rating, 47 to 64 Hz Frequency, 100 kA Short Circuit, 20 kA/ph Peak Surge Current, Modes of Protection: L-N/L-G/N-G, <1 ns Response, Status Indicating Light Indicator, DIN Rail Mounting, Polycarbonate, 3.94 in L x 1.4 in W x 2.28 in H Dimensions

Dimensions      :      3.94 in L x 1.4 in W x 2.28 in H
Indicator Type      :      Status Indicating Light
Material      :      Polycarbonate
Modes of Protection      :      L-N/L-G/N-G
Mounting Type      :      DIN Rail
Peak Surge Current      :      20 kA/ph
Response Time      :      <1 ns
Series      :      LT Series
Electrical Ratings      :      15 A, 25/50 VAC/24/65 VDC
Frequency Rating      :      47 to 64 Hz
Short Circuit Current Rating      :      100 kA
  • Provides surge protection against harmful transient voltages that exceed the nominal operating voltage of AC and DC critical dedicated control loads
  • Compact, fail-safe design allows flexible installation into electrical/control panels
  • Dual component-level fusing (CLF) standard
  • Enhanced transient filter (ETF) standard
  • Reduce lockups, glitches and reprogramming issues
  • Ultra compact, fail-safe design with dual component-level fusing design
  • 100 kA IC short-circuit current rating with a 15 A max Class-T fuse and 5 kA IC with a 15 A breaker
  • Hard-wired via box terminals connection method, #22 to 12 AWG
  • 44 V at L-N mode, A1 ring wave/2 kV/67 A/180 deg phase angle
  • 97 V at L-G mode, A1 ring wave/2 kV/67 A/180 deg phase angle
  • 49 V at N-G mode, A1 ring wave/2 kV/67 A/180 deg phase angle
  • 115 VAC at L-N mode, A3 ring wave/6 kV/200 A/180 deg phase angle
  • 145 V at L-G mode, A3 ring wave/6 kV/200 A/180 deg phase angle
  • 117 VAC at N-G mode, A3 ring wave/6 kV/200 A/180 deg phase angle
  • 197 V at L-N mode, B3/C1 ring wave/6 kV/3 kA/90 deg phase angle
  • 225 V at L-G mode, B3/C1 ring wave/6 kV/3 kA/90 deg phase angle
  • 193 V at N-G mode, B3/C1 ring wave/6 kV/3 kA/90 deg phase angle
  • -40 to 185 deg F operating temperature