Hi-Lume® 3D architectural electronic dimming ballasts are designed to meet the most demanding lighting requirements. By providing industry leading performance with a full-range of 100% to less than 1% fluorescent dimming, Hi-lume 3D ballasts enable you to provide the ideal visual environment for any application.
Hi-Lume® 3D Dimming Ballast, Electronic, Linear/U Bend T8 Fluorescent Lamp, 32 W Lamp, 68.4/67.2/66.5 W, 120/240/277 VAC, 0.57/0.28/0.24 A, 50/60 Hz, Programmed/Rapid Start, 10 deg C Minimum Starting, Total Harmonic Distortion: 0.95, Dimmable: Yes, 2 Lamps, Thermal Protection: Class P, Ballast Factor: 1, NEMA LL9-2009, Threaded Mount, 18 in L x 1 in W x 1.18 in H
Amperage Rating |
: |
0.57/0.28/0.24 A |
Dimensions |
: |
18 in L x 1 in W x 1.18 in H |
Dimmable |
: |
Yes |
Enclosure Type |
: |
NEMA LL9-2009 |
Frequency Rating |
: |
50/60 Hz |
Minimum Starting Temperature |
: |
10 deg C |
Mounting Type |
: |
Threaded |
Number of Lamps |
: |
2 |
Power Factor |
: |
>0.95 |
Thermal Protection |
: |
Class P |
Total Harmonic Distortion |
: |
|
Type |
: |
Electronic |
Wattage |
: |
68.4/67.2/66.5 W |
Lamp Type |
: |
Linear/U Bend T8 Fluorescent |
Lamp Wattage |
: |
32 W |
Voltage Rating |
: |
120/240/277 VAC |
Start Type |
: |
Programmed/Rapid |
Ballast Factor |
: |
1 |
- Hi-Lume® 3D ballasts deliver high dimming ratios and efficiency in a slim-profile enclosure, making it a great choice for low-profile architectural fixtures
- Because Hi-Lume® 3D is microprocessor-controlled, it can operate on the EcoSytem digital control bus and has the ability to listen, think, decide and remember, this provides a new level of flexibility in configuring lighting while saving energy
- Continuous, flicker-free dimming from 100% to less than 1% for T8, 1% for T5 and T5-HO and 5% for T5 Twin-tube
- Programmed rapid start design preheats lamp cathodes before applying full arc voltage to enhance lamp life
- Lamps turn on to any dimmed level without flashing to full brightness
- Low harmonic distortion throughout the entire dimming range maintains power quality
- Frequency of operation ensures that ballast does not interfere with infrared devices operating between 38 and 42 kHz
- Inrush current limiting circuitry eliminates circuit breaker tripping, switch arcing, relay failure and component life degradation
- Ballasts maintain consistent light output for different lamp lengths, ensuring fixture uniformity
- Ultra quiet operation
- Protected from miswires of any input power to control lead, or from lamp leads to each other and ground
- <=90% non condensing relative humidity, 75 deg C max ballast case temperature, class A sound rating
-