Total Protection Solutions™ TK-TT2-065-3Y208-FL Non Stock
printPrint
  1. pin-int

Total Protection Solutions™ TK-TT2-065-3Y208-FL

TK-TT2-065-3Y208-FL Surge Protection Device, TransTrack®2, 120/208 VAC, 47 to 63 Hz, 200 kA SCCR, 3 Phase

  • MPN: TK-TT2-065-3Y208-FL
  • Min. Order Qty: 1
  • Quantity Interval: 1
  • loading loading
Total Protection Solutions™ TK-TT2-065-3Y208-FL

Total Protection Solutions™ TransTrack®2 Surge Protection Device, 120/208 VAC Electrical Rating, 47 to 63 Hz Frequency, 4 Wires, 200 kA Short Circuit, 65 kA/Phase/32.5 kA/Mode Peak Surge Current, Modes of Protection: L-N/L-G/L-L/N-G, <1 ns Response, LED Indicator, 3 ph, Environmental Conditions: 5 to 95% Non-Condensing Relative Humidity, NEMA 4/IP56 Enclosure, Flanged Mounting, 6 in H x 6 in W x 4 in D Dimensions

Dimensions      :      6 in H x 6 in W x 4 in D
Enclosure Type      :      NEMA 4/IP56
Environmental Conditions      :      5 to 95% Non-Condensing Relative Humidity
Indicator Type      :      LED
Modes of Protection      :      L-N/L-G/L-L/N-G
Mounting Type      :      Flanged
Number of Wires      :      4
Peak Surge Current      :      65 kA/Phase/32.5 kA/Mode
Response Time      :      <1 ns
Electrical Ratings      :      120/208 VAC
Frequency Rating      :      47 to 63 Hz
Short Circuit Current Rating      :      200 kA
Phase      :      3
  • Protects facilities and equipment against the harmful effects of lightning strikes and internally generated electrical transients
  • Individually fused MOV's provide superior protection and continuous operation
  • 200 kA IC short-circuit current rating allows direct bus connection without the need of an upstream over-current protection device
  • Includes pre-wired pigtail conductors to stream line installation
  • Low profile design has an optional flush-mount plate for most units for in-wall recessed panel application
  • UL 1283 EMI/RFI filter
  • Ultra compact footprint - makes installation flexible
  • Enhanced transient filter for better protection of electronic loads
  • 4-wire plus ground
  • 3000 impulses per mode repetitive surge current rating, based on actual test data (using ANSI/IEEE C62.41.1-2002 C3 combo wave)
  • Hybrid parallel design with individual fused MOV's and UL 1283 EMI/RFI filter
  • Parallel to electrical distribution system connection method
  • No upstream over-current protection device (breaker or fuse) required
  • Powder coated, impact-resistance steel enclosure
  • Pre-wired with 30 in of 10 AWG (5.26 sq-mm) conductor
  • 150 V for L-N/L-G/N-G, 300 V for L-L MCOV
  • 36 V at L-N mode/283 V at L-G mode/56 V at L-L mode/322 V at N-G mode, A1 ring wave/2 kV/67 A/180 deg phase angle
  • 590 V at L-N mode/597 V at L-G mode/980 V at L-L mode/590 V at N-G mode, B3/C1 impulse wave/6 kV/3 kA/90 deg phase angle
  • 970 V at L-N mode/1160 V at L-G mode/1490 V at L-L mode/1100 at N-G mode, C3 impulse wave/20 kV/10 kA/90 deg phase angle
  • 400/600 V at L-N mode/L-G mode/N-G mode, 800/1000 V at L-L mode UL 1449 voltage protection ratings